3-in-1 Temperature & Security Screener KIOSK

REDUCING THE BIOBURDEN TO LOWER INFECTION RATES

UNIT SPECIFICATIONS

With built-in access control capability

DETAILS:
High-tech temperature screening, face mask detection, and entrance security combined in a single device. Our 3-in-1 system detects body temperature, assesses whether the subject is wearing a face mask, and includes a facial recognition database that can record and identify the subject—and even provide or prevent access based on temperature, presence of mask, or facial identification. When used kiosk style, the 3-in-1 is placed on a stand inside your entrance where individuals will stop briefly to have their temperature checked. A voice alarm will alert if their temperature is elevated. The device can also be programmed to politely remind them to wear a mask if it detects that they’re not wearing one.
SAFETY INSTRUCTIONS:
​
FCC Caution
 
• This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
• This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced technician for help.
• This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.
​
Capture12.PNG

WARNING

​

• Installation and servicing should be performed only by qualified and experienced technicians to conform to all local codes and to maintain your warranty.
• This device is configured for 12V DC operation only. Do not connect to a higher voltage. Use only with NRTL approved Class 2 or LPS power supplies. To prevent potential ground loop issues, a separate PSU should be used for each camera. A multiple-output PSU may be used if the multiple output PSU has isolated and protected (2A max) outputs .

To ensure proper use of this product, please read the instructions carefully.

​

• Read and keep these instructions.
• Ensure that your installation area can safely support 3 times the weight of the device.
• Do not install the device in extreme temperature conditions. Only use the device where temperatures are within the limits shown in the
device specifications. Be especially careful to provide ventilat ion when operating under high temperatures.
• Do not install indoor rated devices where they will be exposed to rain or moisture.
• To prevent damage to the image, do not aim the device toward an extreme light source.
• Do not touch the device lens, dome or bezel (front glass plate).
• Do not drop the device or subject it to physical shock.
• Do not use strong or abrasive cleaners, clean only with a soft cloth and mild detergent or alcohol.
• Do not open the device or attempt to service it yourself. Refer all service issues to your dealer.

Capture3.PNG

INSTALLATION

Rack Mounting
Fix the face recognition device onto the turnstile or a rack with the rack
mounting bracket provided.
4.PNG
Wall or Stand Mounting

Cable:

RJ45 Network interface used for Internet and LAN communication.
RS485 Used to expand other sensors. Input biometric equipment, NFC card reader and other 485 communication
sensors (need to be connected by R&D).
Alarm In
It is used for the external alarm equipment. When the alarm equipment inputs a signal, it can interact with the integrated
machine to generate an action. For example, when a door magnetic alarm is connected, when someone
opens the door, it will trigger the integrated machine to take a photo of the door and upload it to the mailbox.
Alarm Out1 & Alarm Out2 It can output the door opening signal to control the gate and access control. Or the output alarm signal is
connected to an external alarm. When high temperature detected , it gives alarm.
Wiegand Output It used to control external access control controller using Wiegand protocol.
Mic In Connect external microphone to pick up audio.
Audio Out Use to connect external speaker to amplify the device vice broadcast.
DC12V Used to connect 12V DC power supply to the device.

Fix the wall bracket on the wall or stand. Place the face recognition
device on the bracket and slide it down to fix it properly in place.
4.PNG
6.PNG
OPERATING INSTRUCTIONS
Open web browser and input the IP Address on the address bar displayed on the device screen. Turn on the Temperature Measurement and Detection function.
Step 1
Go to Intelligent Analysis > Face Detection > Basic. Check the
Temperature Detection box to turn on the function. You can set the
temperature unit and alarm temperature in this setting.
Step 2
Place the face in the designated detection frame to measure the
temperature. The specific temperature will be displayed during the
recognition check and there will be Normal/Abnormal temperature
voice announcements.
Note: Please remove your sunglasses, hat and move hair from you
forehead for proper temperature measurement.
Step 3
Go to Intelligent Analysis > Face Detection > Recognition Record.
There will be information records such as the body temperature of the
captured person and other details.
7.PNG
8.PNG
9.PNG
SPECIFICATIONS
Temperature & Mask Detection
Interface
Facial Recognition
Temp. Measurement Range 86°F to 104° F
Temp. Accuracy ± 0.54°F (0.3°C)
Detection Distance 12” to 24”
Temp. Detection Support
Mask Detection Support
Voice Alarm Support for both abnormal temp.
and no mask
Ethernet 10M / 100M Ethernet, RJ45 Port
Wiegand Interface 1 pc for output
RS232 & RS485 Support
Alarm Output Support
Micro SD Card Built-in 32GB; Support for up to
128GB
Audio Input & Output Support, with built-in speaker
Recognition Accuracy ≥ 99.7%
Recognition Time < 1 s
Face Database ≥ 20,000 faces
Recognition Dist. & Height Distance: 20” to 79”
Height: 47” to 87”, adjustable
Recognized Face Angle ≥ 30°
Lens Angle 2.8 mm, H 117.8°, V 64.1°,
D 141.9°
Blacklist & Whitelist Support
General
General
Working Temp. -22°F to 122°F
Working Humidity RH 5~90%
Power Supply DC12V 3.33A
Power Consumption ≤ 20 W
Dimensions 10.75” x 5.67” x 0.98”
Diameter for Install on Gate 1.18”
Screen Size 8”, full-view IPS LCD screen
Weight 5.5 lbs (without stand)
Installation Wall mount or stand/gate mount
SETTINGS
Mask Detection
Sky Eye Cloud Platform (Optional)
Basic Settings
Go to Intelligent Analysis > Face Detection > Basic. You can
enable or disable Mask Detection. If it’s enabled, it gives you voice
announcements when the person is detected without mask and it
restricts the person to access the entry.
For centralized monitoring, there is a cloud platform for JVS-FRT-P8.
To log-in, open your browser and enter http://facemgr.deepcam.cn/
in the URL bar. A login page will open. Register an account first to use
this Cloud Platform. Once the account is verified, you can login .
Go to Intelligent Analysis > Face Detection > Basic. By default,
Face Detection is enabled. You can adjust other parameters here.
Recommended Settings: Sensitivity = 2 and Threshold = 75.
Email Settings
Face Import & Database
Firmware Update
1. Go to Network > Advanced Configuration > Alarm Email. Input
your information.
2. Then choose Test Email. It will send a test email to all the recipients
added in it. If the test mail failed, check the details you entered in
the Alarm Email settings.
1. Go to Intelligent Analysis > Face Detection > Face Import. First
edit the pictures according to the specification requirements below.
The format must be .jpg format and cannot exceed 512KB; the file
name must be: name_number_gender.jpg; the max. resolution
should be 960x960, and the min. should be 30x30
Click Upload White List, Upload Black List or Upload VIP List buttons
to upload the faces into the database.
2. Go to Intelligent Analysis > Face Detection > Face Database.
Once the image uploaded successfully, you can View, Edit and
Remove the pictures from the database.
Go to System > Maintenance. Select File Update as the update
method. Choose Version File and Update File from the directory. Click
on the Update button to update the device firmware.
Device Management
Recognition Record
Subject Management
You can manage devices in this section. Under Device List, click on
Create Device to add a new device. Also, you can Edit or Delete added
devices from the Device List.
Go to Intelligent Analysis > Face Detection > Recognition Record.
If the verification is successful, the specific date & time and other
information of the person will be displayed in the Recognition Record.
Face Attendance
Face Attendance
Go to Tools > Face Attendance to monitor the attendance record.
In Access Records, you can see the face recognition records with body
temperature, date and time. Also, you can export the records.
In Subject Management, you can add subjects, upload face images
and input necessary details like Name, ID No., Gender, Role etc. When
done, click the Submit button. Once you added the subject successfully,
you can see the subject list.
Batch Import is also available in the Subject Management page. When
you click on Batch Import, select Download template first and prepare
the face image and other details according to the template. Then click
Select File and choose the files to import into the platform.
In this Subject management page, you can also Edit or Delete added
subjects. Also, you can export the subject list from here.
bottom of page